home *** CD-ROM | disk | FTP | other *** search
Text File | 1993-12-13 | 7.6 KB | 189 lines | [TEXT/ttxt] |
-
- AppleOrder 2.0 Modem Command and Connection String Settings
- (as of 2/16/93)
-
- Modem Connection Settings Status
- ___________________________________________________________________
- Generic HayesCompatible CCL: XUSA Software_MNP.CCL Tested
- (covers most modems) ModemCmd: AT&FE0X4V1
- ConnectStr: CONNECT
- Note: This CCL replaces “USA Software_MNP.CCL” used in AppleOrder 1.0
- ___________________________________________________________________
- Generic MNP or V.42 CCL: XUSA Hardware_MNP.CCL Tested
- Compatible ModemCmd: AT&FV1\V1\N2
- (covers most MNP or ConnectStr: “REL” or “CONNECT baudrate”
- V.42 capable modems) as in “CONNECT 2400”
- Note: This CCL replaces “MNP Compatible.CCL” used in AppleOrder 1.0 ___________________________________________________________________
- Apple Personal 1200 CCL: XUSA Software_MNP.CCL Tested
- ModemCmd: AT&FE0X1V1
- ConnectStr: CONNECT
-
- Apple 2400 CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd:
- AT&FV1\V1X4&C1&L0&D2\Q1\X0\T0\N2\K5
- ConnectStr: REL
-
- Apple Powerbook Internal CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FV1\V1X4&C1&L0&D2\N2
- ConnectStr: CONNECT
-
- Apple Duo Express Internal CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FE0X4W1&Q5
- ConnectStr: CONNECT
-
- Abaton CCL: XUSA Hardware_MNP.CCL UNTESTED
- ModemCmd: AT&FE0X4V1\N2
- ConnectStr: CONNECT
-
- Avatex CCL: XUSA Software_MNP.CCL Tested
- ModemCmd: AT&F
- ConnectStr: CONNECT
-
- BusinessLand CCL: XUSA Hardware_MNP.CCL UNTESTED
- ModemCmd: AT&FE0X4V1\N2\G0
- ConnectStr: CONNECT
-
- EMAC MD2400 CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FV1\V1\N2
- ConnectStr: REL
-
- Everex CCL: XUSA Hardware_MNP.CCL UNTESTED
- ModemCmd: AT&FE0X4V1\N2
- ConnectStr: CONNECT
-
- Farallon Remote/V.32 CCL: XUSA Hardware_MNP.CCL UNTESTED
- ModemCmd: AT&FE0X4V1$MB2400$BA&E0
- ConnectStr: CONNECT
-
- Farallon V.42bis 9600 CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FX4&D0&E1&E5&E7&E10&E12
- ConnectStr: RELIABLE
-
-
- Hayes V.42 series CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FV1&Q5W1S48=128S36=4&K4
- ConnectStr: CONNECT
-
- Intel 9600EX,2400EX CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&F\V2\N4
- ConnectStr: REL-MNP
-
- Logic Code QuickTell 2400 CCL: XUSA Hardware_MNP.CCL Tested
- Model V.42bis ModemCmd: AT&FV1X4\N2
- ConnectStr: CONNECT 2400
-
- Microcom CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FE0X4V1\N2
- ConnectStr: CONNECT
-
- Microcom AX/2400 CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd:
- AT&F\V1X4&C1&L&D2\Q1\X0\T0\N2\K5\J0
- ConnectStr: REL
-
- MicrocomQX series CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FE0X4V1\Q0\N2
- ConnectStr: CONNECT
-
- MultiTech CCL: XUSA Hardware_MNP.CCL UNTESTED
- ModemCmd: AT&FE0X4V1$BA&E0
- ConnectStr: CONNECT
-
- MultiTech 212EH CCL: XUSA Hardware_MNP.CCL UNTESTED
- ModemCmd: AT&FV1&E2&Q0
- ConnectStr: RELIABLE
-
- NEC N24321 CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FV1L2
- ConnectStr: ARQ
-
- Practical Peripherals CCL: XUSA Hardware_MNP.CCL Tested
- PM2400SA V.42 ModemCmd1: AT&F&C1&D2&K3&Q5W2S95=44 {or try:}
- ModemCmd2: AT&F&C1&D2&K3&Q5
- ConnectStr: CONNECT {or LAP-M}
-
- Prometheus ProModem CCL: XUSA Hardware_MNP.CCL Tested
- 9600 Plus ModemCmd: AT&F&FX4*E2*F0*S0
- ConnectStr: ARQ
-
- Prometheus ProModem CCL: XUSA Hardware_MNP.CCL Tested
- Ultima ModemCmd: AT&FV1*E2*F3
- (S/N begins with FDxxxx) ConnectStr: CONNECT 2400 EC
-
- Racal Vadic 9600 CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FV1*E1
- ConnectStr: CONNECT
-
- Shiva NetModem E/9600 CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FV1&Q5
- ConnectStr: CONNECT 9600
-
- Shiva NetSerial Match ModemCmd and ConnectStr to the attached
- modem. If the modem supports hardware EC in the
- form of MNP or V.42, use XUSA Hardware,
- otherwise use XUSA Software CCL.
-
- SupraFax V.32 9600 CCL: XUSA Hardware_MNP.CCL UNTESTED
- ModemCmd: AT&F1\N2
- ConnectStr: CONNECT
-
- Telebit CCL: XUSA Hardware_MNP.CCL UNTESTED
- ModemCmd: AT&FS50=3S51=2S95=0
- ConnectStr: CONNECT
-
- Telebit T1000 CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd:
- AT&F~&FS50=0S58=0S66=1S95=1S68=3X3
- ConnectStr: REL
-
- UDS EC224A/D CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd:
- AT&FE%U1X4&C1&LY&D2%V2%N2%L%L3%L1%M1%B5
- ConnectStr: SYNC PROTOCOL 4
-
- US Robotics CCL: XUSA Software_MNP.CCL Tested
- ModemCmd: AT&FL1&M0S0=0E0V1X1
- ConnectStr: CONNECT
-
- US Robotics Courier CCL: XUSA Hardware_MNP.CCL UNTESTED
- ModemCmd: AT&FE0X4V1&M0&H2&K0
- ConnectStr: CONNECT
-
- US Robotics Courier HST CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FV1&I2&H2&M5&A3X6
- ConnectStr: MNP
-
- US Robotics Sportster V.42 CCL: XUSA Hardware_MNP.CCL UNTESTED
- ModemCmd: AT&F&M4&W
- ConnectStr: CONNECT
-
- Ventel 9600 Plus CCL: XUSA Hardware_MNP.CCL Tested
- ModemCmd: AT&FX4V1\V1\N2
- ConnectStr: CONNECT 2400/REL (or 9600/REL)
-
-
- NOTE: See following page for Technical Support Phone Numbers
-
-
- Technical Support
- Modem Manufacturer Phone #:
-
- Abaton (div of Everex) (510) 683-2226
- AST Research (714) 727-9630
- Dove Corp. (919) 343-5610
- EMAC (div of Everex) (510) 498-4440
- Hayes (404) 441-1617
- Intel Corp. (503) 629-7000
- Logic Code Systems (805) 388-9000
- Microcom (617) 551-1000
- Multi-Tech Systems (612) 785-3500
- Practical Peripherals (805) 496-7707
- Prometheus (503) 692-9601
- Racal Vadic (408) 432-8008
- Shiva Corp. (617) 252-6400
- Telebit Corp. (408) 734-4333
- US Robotics (708) 982-5010
- Ventel (408) 437-7400
-
-
-